Basic Info.

Model NO.:3021
Application:Electrical Base, Shell
Type:Insulation Paper
Chemistry:Inorganic Insulation
Material:Paper
Thermal Rating:E 120
Maximum Voltage:<10KV
Thickness:0.4-100mm
Trademark:Redsun
Transport Package:Carton & Pallet
Specification:JB
Origin:China
HS Code:3921909010

Product Description

Temperature classification is E. Excellent machining and dielectric properties. Used as the insulating structural parts in oil-immersed type transformer and capacitor.
 
Nominal thicknessTolerance Nominal thicknessTolerance
mm  mmmmmm
0.4± 0.078± 0.47
0.5± 0.0810± 0.55
0.6± 0.0912± 0.62
0.8± 0.1014± 0.69
1± 0.1216± 0.75
1.2± 0.1420± 0.86
1.6± 0.1625± 1.00
2± 0.1930± 1.15
2.5± 0.2235± 1.25
3± 0.2540± 1.35
4± 0.3045± 1.45
5± 0.3450± 1.55
6± 0.37  
Note: 1. The other tolerances are negotiated by customer and supplier.
2. The tolerance of preferred thickness should adopt the bigger one if the one of preferred thickness for nominal thickness is not listed in the table.
3. Normal dimension: 960± 15mm× 1460± 15mm, 960± 15mm× 1960± 15mm
     
 
NoProperitiesUnitNominal thickness used for test
mm
Normal Value
1Flexural strength, perpendicular to layerMpa≥ 1.6≥ 120
2Apparent flexural elastic modulusMpa≥ 1.6≥ (7000)
3Compressive strength, perpendicular to layerMpa≥ 5≥ (250)
4Shear strength, parallel to the layerMpa≥ 5≥ (10)
5Tensile strengthMpa≥ 1.6≥ (100)
6Bonding strengthN≥ 10≥ 3200
7Electric strength, perpendicular to the layer, at 90± 2 ° C  CoilMV/m≤ 3Refer to table 3
8Breakdown voltage 1, perpendicular to layer, at 90 ± 2 ° C  CoilkV≥ 3≥ 20
9Comparative dielectric constantunder 48Hz-62 Hz.-≤ 3-
under 1MHz.≤ 3≤ 5.5
10Dissipation factorUnder 48Hz-62 Hz-≤ 3-
under 1MHz≤ 3≤ 0.05
11Insulation resistance after immersing in waterWAll≥ 1× 10 7
12Comparative tracking index.-≥ 3≥ (100)
13Heat resistance for long time.-≥ 3≥ (105)
14Load deformation temperature° C under consideration
15Densityg/cm 3All(1.3-1.4)
16Water absorptionmgAllRefer to table 4
Note: The value in the parenthesis is typical value. Not used as the requirement only for reference.
1. Pre-conditioning for 96h at 105 ° C before testing, then having the test at once.
 
 
Mean thickness
  mm
Electric strength
MV/m
 Mean thickness mmElectric strength
MV/m
0.4≥ 15.71.6≥ 10.1
0.5≥ 14.71.8≥ 9.6
0.6≥ 14.02.0≥ 9.3
0.7≥ 13.42.2≥ 9.0
0.8≥ 12.92.4≥ 8.8
0.9≥ 12.52.6≥ 8.6
1.0≥ 12.12.8≥ 8.5
1.2≥ 11.43.0≥ 8.4
1.4≥ 10.7  
Note:
1, Electric strength perpendicular to layer direction at 90± 2 ° C  Coil can optional choose one 20s raising voltage class by class and the requirement of voltage resistance test for 1 min. If the material is conformed with one of the both methods, the electric strength shall be considered to be also conform with the standard.
2, If the arithmetic average of the sample thickness is between the both thicknesses listed in the above table, its requirement value shall use the interpolation method to get. If the average is below 0.4mm, the requirement value of electric strength shall use the one of 0.4mm, If the normal thickness is 3mm and the average of the sample thickness is over 3mm, the requirement value of 3mm shall be used.
     
 
 
Mean thickness mmWater absorption
mg
 Mean thickness
mm
Water absorption
  mg
0.4≤ 1605.0≤ 235
0.5≤ 1626.0≤ 250
0.6≤ 1638.0≤ 285
0.8≤ 16710.0≤ 320
1.0≤ 17012.0≤ 350
1.2≤ 17414.0≤ 390
1.6≤ 18216.0≤ 420
2.0≤ 19020.0≤ 490
2.5≤ 19525.0≤ 570
3.0≤ 200Processed by one side to 22.5≤ 684
4.0≤ 220
Note: 1: If the arithmetic average of the sample thickness is between the both thicknesses listed in the above table, its requirement value shall use the interpolation method to get.
        2: If the average is below 0.4mm, the requirement value of water absorption shall use the one of 0.4mm. If the normal thickness is 25mm and the average of the sample' s thickness is over 25mm, the requirement value of 25 mm shall be used. If the thickness of the laminates is 25, it shall be processed to 22.5mm by one-side frame and the surface shall be smooth.
Send your message to this supplier
Avatar
Ms. Liu Hui
Marketing Manager
*From
To Ms. Liu Hui
*Message
Enter between 20 to 4,000 characters.
This is not what you are looking for? Post a Sourcing Request Now
Find Similar Products By Category:

Beijing Red Sun Composite Material Co., Ltd.

- Beijing, China
- Manufacturer/Factory

Gold Member Since 2011
Audited Supplier
  • Sample Available
  • OEM/ODM Service